Article ID: 000080343 Content Type: Error Messages Last Reviewed: 04/07/2020

Error (170012): Fitter requires "XXX" LABs to implement the design, but the device contains only "XXX" LABs

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro edition software version 19.4, you may see the above error when using VQM netlist as source for the compilation in Intel® Stratix® 10 Devices.

    The Intel Quartus Prime Pro edition software version 19.4 does not support "WYSIWYG primitives " resynthesis. If a VQM File contains WYSIWYG primitives, the Intel Quartus Prime Compiler creates atom representations from those WYSIWYG primitives as it synthesizes the design, so that the atoms preserve the WYSIWYG structure of the netlist file. 

    Resolution

    A patch is avaliable to fix this problem for the Intel® Quartus® Prime Pro Edition software version 19.4. Download and install Patch 0.05 from the appropriate link below

    Download the version 19.4  Patch 0.05 for Windows(.exe).

    Download the version 19.4 Patch 0.05 for Linux (.run).

    Download the Readme for Patch 0.05 (.txt).


    This problem is fixed starting with the Intel® Quartus® Prime Pro Edition software version 20.1.

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs