Article ID: 000081971 Content Type: Troubleshooting Last Reviewed: 10/17/2014

Incorrect TrustZone Information in SoC Technical Reference Manual

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    The Arria V Device Handbook and Arria V Device Handbook contain incorrect information about the TrustZone security level for the transactions initiated by the Ethernet MAC and ETR master interfaces. The Interconnect chapter of Volume 3: Hard Processor System Technical Reference Manual in these handbooks incorrectly indicates that these transactions are nonsecure.

    Resolution

    The following table lists the correct TrustZone security levels for transactions from these component’s masters.

    Interconnect Master Interface
    MastersTrustZone Security
    EMAC 0/1Secure
    ETRPer Transaction

    Related Products

    This article applies to 2 products

    Arria® V FPGAs and SoC FPGAs
    Cyclone® V FPGAs and SoC FPGAs