Article ID: 000082378 Content Type: Troubleshooting Last Reviewed: 08/15/2023

Why can't I program my Intel® Stratix® 10 device using a . JAM file?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Jam™ STAPL software
  • Intel® FPGA Programming Software
  • Configuration Clock Intel® Stratix® 10 FPGA IP
  • Configuration and Programming
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem starting in the Intel® Quartus® Prime software version 17.1, you will not be able to program a . JAM file in certain Intel Stratix® 10 devices. This problem is seen both when using the JAM™ STAPL Player, as well as the Quartus JLI utility to program the device.

    You might see the following failure message when using the Quartus JLI utility-

    Error status: Request failed
    CONF_DONE pin failed to go high at device #1
    No response from device
    Exit code = 23... No response from device

     

     

    Resolution

    To work around this JAM programming problem, regardless of whether you see the error above, click on the following link to download a patch for Intel® Quartus® Prime 17.1.1-

    Download patch

    This problem is fixed starting with the Intel® Quartus® Prime Software version 18.0.