Article ID: 000083067 Content Type: Troubleshooting Last Reviewed: 12/15/2014

"Error: PowerPlay Power Analyzer (quartus_pow) cannot be run -- target family MAX 10 FPGA is not supported"

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    You cannot enable the PowerPlay Power Analyzer for the MAX® 10 device in the Quartus® II software release version 14.0 update 2. When compiling your design, the Quartus II software generates the following error:

    Error: PowerPlay Power Analyzer (quartus_pow) cannot be run -- target family MAX 10 FPGA is not supported
    Resolution

    The PowerPlay Power Analyzer is not supported for the MAX® 10 device in the Quartus II software release version 14.0 update 2. You must remove the FLOW_ENABLE_POWER_ANALYZER setting from your project Quartus II Settings File (.qsf) file, or set the FLOW_ENABLE_POWER_ANALYZER value to OFF.

    This issue will be fixed in a future release of the Quartus II software.

    Related Products

    This article applies to 1 products

    MAX® II CPLDs