Article ID: 000084445 Content Type: Install & Setup Last Reviewed: 11/26/2014

How do I regenerate the Stratix V IP for PCIe?

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Quartus® II software version 13.1 and earlier, you may see the following error when you regenerate the IP for PCIe if you have opened the IP wizard without a Stratix® V project being open.

    Error: Simulation model generation failed: <installation path>//sopc_builder/bin/ip-make-simscript --spd=<project path>/<instance name>.spd --output-directory=<project path>/<instance name>_sim

    Resolution

    To work around this problem, open or create a Stratix V project before launching the IP wizard.

    This problem is scheduled to be fixed in a future release of the Quartus II software.