Article ID: 000085712 Content Type: Install & Setup Last Reviewed: 11/04/2013

EMIF Generation for Arria V or Cyclone V Devices Requires Stratix V Device Database to be Installed

Environment

  • Quartus® II Subscription Edition
  • Simulation
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    This problem affects DDR2, DDR3, LPDDR2 and RLDRAM II products.

    When generating an external memory interface for an Arria V or Cyclone V device, the generation process may fail to complete if you do not have the Stratix V device database installed.

    Resolution

    The workaround for this issue is to ensure that the Stratix V device database is installed before attempting to generate the external memory interface.

    This issue will be fixed in a future version.

    Related Products

    This article applies to 2 products

    Arria® V FPGAs and SoC FPGAs
    Cyclone® V FPGAs and SoC FPGAs