Article ID: 000086712 Content Type: Install & Setup Last Reviewed: 10/29/2021

Why does partial reconfiguration fail on Intel® Stratix® 10 devices in designs compiled with the Intel® Quartus® Prime Pro Edition Software v19.2?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Altera S10 Mailbox Client Core
  • Stratix® 10 Serial Flash Mailbox Client Intel® FPGA IP
  • Temperature Sensor Intel® Stratix® 10 FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Edition Software v19.2, a partial reconfiguration operation may fail in designs targeting an Intel® Stratix® 10 device that includes any of the following intellectual property (IP) cores: the Temperature Sensor Intel® Stratix® 10 FPGA IP core, the Intel® Stratix® 10 Serial Flash Mailbox Client Intel® FPGA IP core or the Mailbox Client Intel® Stratix® 10 FPGA IP core.

    Resolution

    A patch is available to fix this problem for the Intel® Quartus® Prime Pro Edition Software v19.2. Download and install Patch 0.03 from the following links:

    This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software v19.3.

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs