Article ID: 000087025 Content Type: Troubleshooting Last Reviewed: 10/21/2011

The CUSTOM PHY MegaWizard Plug-In Manager does not prevent illegal combinations of Data rate and Input clock frequency for Stratix V

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    The CUSTOM PHY MegaWizard Plug-In Manager does not prevent illegal combinations of Data rate and Input clock frequency.If you enter illegal an illegal combination, during compilation, the Quartus II software might generate messages similar to the following:

    Warning: altera_xcvr_custom_phy: Simulation libraries for Mentor simulators may not be present.

    Resolution

    The Data rate should be a minimum of 622 Mbps and a maximum of 6.5 Gbps.

    Related Products

    This article applies to 1 products

    Stratix® V FPGAs