Article ID: 000089288 Content Type: Error Messages Last Reviewed: 02/27/2023

Warning(208542): Fault injection IP on device <number> does not have enough memory to store frame error.

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    In Intel® Stratix® 10 devices and Intel Agilex® 7 devices, this warning message is displayed when injecting more than 8 errors continuously without the Read EMR using the Fault Injection Debugger.  

    This is because the Error Message Register (EMR) can only. 

    Resolution

    Click Read EMR to read out error messages and clear the Error Message Register (EMR).  Then the warning will not be issued unless more than 8 errors are injected again without the Read EMR. 

    Related Products

    This article applies to 2 products

    Intel Agilex® 7 FPGAs and SoC FPGAs
    Intel® Stratix® 10 FPGAs and SoC FPGAs