1.4. Recommended Operating Conditions

Table 2.  Recommended Operating Conditions
Operating Condition Range of Values
Ambient operating temperature range 0 °C to 30 °C
ICC load current 195 A
ICC load transient percentage 200 A/µs
FPGA maximum power supported by active heatsink/fan 160 W2

When handling the board, it is important to observe static discharge precautions.

CAUTION:
Without proper anti-static handling, the board can be damaged. Therefore, use anti-static handling precautions when touching the development kit.
Note: This development kit should not be operated in a vibration environment.
2 160W for core and 60W for FGT Transceiver