Agilex™ 7 FPGAs and SoCs Device Data Sheet: M-Series

ID 769310
Date 4/01/2024
Public
Document Table of Contents

General Configuration Timing Specifications

Table 85.  General Configuration Timing Specifications For specification status, see the Data Sheet Status table
Symbol Description Requirement Unit
Min Max
tCF12ST1 nCONFIG high to nSTATUS high 20 ms
tCF02ST0 nCONFIG low to nSTATUS low 400 ms
tST0 nSTATUS low pulse during configuration error 0.5 10 ms
tCD2UM 127 CONF_DONE high to user mode 5 ms
tST12CF0 Minimum time to drive nCONFIG from high to low after nSTATUS transitions from low to high 0 ms
tST02CF1 Minimum time to drive nCONFIG from low to high after nSTATUS transitions from high to low 0 ms
Figure 26. General Configuration Timing Diagram
Note: CONF_DONE and INIT_DONE are de-asserted during device clean state after full device reconfiguration is triggered.
127 This specification is the initialization time that indicates the time from CONF_DONE signal goes high to INIT_DONE signal goes high.